Asphalt Concrete Plant equipped with Fuel Consumption Monitoring System

Task: organize remote control of the actual fuel consumption of a diesel burner and generator, receive data at the place of operation.

Composition of the monitoring system: two DFM Marine 2000 flow meters, MasterCan Display 35 U, bypass valves and a fuel filter.

Mounting features: crimp mounting kits are used, all system components are placed in special boxes for additional protection against external influences and vandalism.

Estimated payback period of the system: 3 months.

A useful case about diesel generators can be viewed at the link.

MasterCAN Display 35 U is installed in the generator system.

Data on hourly and total fuel consumption are displayed on the MaterCAN Display 35 U screen.

DFM Marine 2000 Fuel flow meter for heavy equipment

Fuel system of the generator.

Fuel hoses.

DFM Marine and MasterCAN Display 35 U are installed in special boxes for additional protection.